Please use this identifier to cite or link to this item: https://ah.lib.nccu.edu.tw/handle/140.119/66923
題名: Improvement of Suboptimal Siphon- and FBM-Based Control Model of a Well-Known S3PR
作者: 趙玉
Chao, D.Y.
貢獻者: 資管系
日期: 2011
上傳時間: 25-Jun-2014
摘要: Siphon-based deadlock control of Flexible Manufacturing System (FMS) runs faster by avoiding reachability analysis, but reaches fewer states than an optimal. First-met bad marking (FBM) method requires more monitors, but reaches more states by refining some monitors with smaller (hence less disturbed) controller regions. However, the same refinement leads to more monitors for other siphons, which can be combined without losing states. This paper develops the formal theory to uncover the secret behind the above discrepancy. It improves the siphon-based approach to reach more states while using fewer monitors.
關聯: IEEE Transactions on Automation Science and Engineering, 8(2), 404-411