Please use this identifier to cite or link to this item: https://ah.lib.nccu.edu.tw/handle/140.119/71538
題名: Influence of Dynesys system screw profile on adjacent segment and screw
作者: 施世亮
Liu, Chien-Lin ; Zhong, Zheng-Cheng ; Shih, Shih-Liang ; Huang, Chinghua ; Lee, Yong-Eng ; Chen, Chen-Sheng
貢獻者: 神科所
日期: Aug-2010
上傳時間: 19-Nov-2014
摘要: Study Design: Displacement-controlled finite element analysis was used to evaluate the mechanical behavior of the lumbar spine after insertion of the Dynesys dynamic stabilization system. Objective: This study aimed to investigate whether different depths of screw placement of Dynesys would affect load sharing of screw, range of motion (ROM), annulus stress, and facet contact force. Summary of Background Data: In clinical follow-up, a high rate of screw complications and adjacent segment disease were found after using Dynesys. The pedicle screw in the Dynesys system is not so easy to implant into the standard position and causes the screw to protrude more prominently from the pedicle. Little is known about how the biomechanical effects are influenced by the Dynesys screw profile. Methods: The Dynesys was implanted in a 3-dimensional, nonlinear, finite element model of the L1 to L5 lumbar spine. Different depths of screw position were modified in this model by 5 and 10mm out of the pedicle. The model was loaded to 150 N preload and controlled the same ROMs by 20, 15, 8, and 20 degrees in flexion, extension, torsion, and lateral bending, respectively. Resultant ROM, annulus stress, and facet contact force were analyzed at the surgical and adjacent level. Results: Under flexion, extension, and lateral bending, the Dynesys provided sufficient stability at the surgical level, but increased the ROM at the adjacent level. Under flexion and lateral bending, the Dynesys alleviated annulus stress at the surgical level, but increased annulus stress at the adjacent level. Under extension, the Dynesys decreased facet loading at the surgical level but increased facet loading at the adjacent level. Conclusions: This study found that the Dynesys system was able to restore spinal stability and alleviate loading on disc and facet at the surgical level, but greater ROM, annulus stress, and facet loading were found at the adjacent level. In addition, profile of the screw placement caused only a minor influence on the ROM, annulus stress, and facet loading, but the screw stress was noticeably increased.
關聯: Journal of spinal disorders & techniques, 23(6), 410-417
資料類型: article
Appears in Collections:期刊論文

Files in This Item:
File Description SizeFormat
index.html176 BHTML2View/Open
Show full item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.