Please use this identifier to cite or link to this item: https://ah.lib.nccu.edu.tw/handle/140.119/63785
DC FieldValueLanguage
dc.contributor應物所en_US
dc.creator蔡尚岳zh_TW
dc.creatorTsai, Shang-Yueh ; Otazo, Ricardo ; Posse, Stefan ; Lin, Yi-Ru ; Chung, Hsiao-Wen ; Wald, Lawrence L. ; Wiggins, Graham C. ; Lin, Fa-Hsuanen_US
dc.date2008.04en_US
dc.date.accessioned2014-02-11T06:02:20Z-
dc.date.available2014-02-11T06:02:20Z-
dc.date.issued2014-02-11T06:02:20Z-
dc.identifier.urihttp://nccur.lib.nccu.edu.tw/handle/140.119/63785-
dc.description.abstractParallel imaging has been demonstrated to reduce the encoding time of MR spectroscopic imaging (MRSI). Here we investigate up to 5-fold acceleration of 2D proton echo planar spectroscopic imaging (PEPSI) at 3T using generalized autocalibrating partial parallel acquisition (GRAPPA) with a 32-channel coil array, 1.5 cm3 voxel size, TR/TE of 15/2000 ms, and 2.1 Hz spectral resolution. Compared to an 8-channel array, the smaller RF coil elements in this 32-channel array provided a 3.1-fold and 2.8-fold increase in signal-to-noise ratio (SNR) in the peripheral region and the central region, respectively, and more spatial modulated information. Comparison of sensitivity-encoding (SENSE) and GRAPPA reconstruction using an 8-channel array showed that both methods yielded similar quantitative metabolite measures (P > 0.1). Concentration values of N-acetyl-aspartate (NAA), total creatine (tCr), choline (Cho), myo-inositol (mI), and the sum of glutamate and glutamine (Glx) for both methods were consistent with previous studies. Using the 32-channel array coil the mean Cramer–Rao lower bounds (CRLB) were less than 8% for NAA, tCr, and Cho and less than 15% for mI and Glx at 2-fold acceleration. At 4-fold acceleration the mean CRLB for NAA, tCr, and Cho was less than 11%. In conclusion, the use of a 32-channel coil array and GRAPPA reconstruction can significantly reduce the measurement time for mapping brain metabolites. Magn Reson Med 59:989–998, 2008. © 2008 Wiley-Liss, Inc.en_US
dc.format.extent1150044 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoen_US-
dc.relationMagn Reson Med, 59(5), 989-998en_US
dc.subjectproton echo planar spectroscopic imaging; PEPSI; MR spectroscopic imaging; parallel MRI; 32en_US
dc.titleAccelerated Proton-Echo-Planar-Spectroscopic-Imaging using GRAPPA with a 32-Channel Phase Array Coilen_US
dc.typearticleen
item.fulltextWith Fulltext-
item.languageiso639-1en_US-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.grantfulltextrestricted-
item.cerifentitytypePublications-
Appears in Collections:期刊論文
Files in This Item:
File Description SizeFormat
989-998.pdf1.12 MBAdobe PDF2View/Open
Show simple item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.