Please use this identifier to cite or link to this item: https://ah.lib.nccu.edu.tw/handle/140.119/65803
DC FieldValueLanguage
dc.contributor應物所en_US
dc.creator蔡尚岳zh_TW
dc.creatorTsai, Shang-Yuehen_US
dc.date2007.12en_US
dc.date.accessioned2014-05-01T09:47:42Z-
dc.date.available2014-05-01T09:47:42Z-
dc.date.issued2014-05-01T09:47:42Z-
dc.identifier.urihttp://nccur.lib.nccu.edu.tw/handle/140.119/65803-
dc.description.abstractMR spectroscopic imaging (MRSI) with whole brain coverage in clinically feasible acquisition times still remains a major challenge. A combination of MRSI with parallel imaging has shown promise to reduce the long encoding times and 2D acceleration with a large array coil is expected to provide high acceleration capability. In this work a very high-speed method for 3D-MRSI based on the combination of proton echo planar spectroscopic imaging (PEPSI) with regularized 2D-SENSE reconstruction is developed. Regularization was performed by constraining the singular value decomposition of the encoding matrix to reduce the effect of low-value and overlapped coil sensitivities. The effects of spectral heterogeneity and discontinuities in coil sensitivity across the spectroscopic voxels were minimized by unaliasing the point spread function. As a result the contamination from extracranial lipids was reduced 1.6-fold on average compared to standard SENSE. We show that the acquisition of short-TE (15 ms) 3D-PEPSI at 3 T with a 32 × 32 × 8 spatial matrix using a 32-channel array coil can be accelerated 8-fold (R = 4 × 2) along y-z to achieve a minimum acquisition time of 1 min. Maps of the concentrations of N-acetyl-aspartate, creatine, choline, and glutamate were obtained with moderate reduction in spatial-spectral quality. The short acquisition time makes the method suitable for volumetric metabolite mapping in clinical studies. Magn Reson Med, 2007. © 2007 Wiley-Liss, Inc.en_US
dc.format.extent814881 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoen_US-
dc.relationMagn Reson Med, 58(6), 1107-1116en_US
dc.subjectecho-planar spectroscopic imaging;parallel imaging;SENSE;regularization;large array coilen_US
dc.titleAccelerated Short-TE 3D Proton-Echo-Planar-Spectroscopic-Imaging using 2D-SENSE with a 32-Channel Array Coilen_US
dc.typearticleen
item.fulltextWith Fulltext-
item.languageiso639-1en_US-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.grantfulltextrestricted-
item.openairetypearticle-
Appears in Collections:期刊論文
Files in This Item:
File Description SizeFormat
21426.pdf795.78 kBAdobe PDF2View/Open
Show simple item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.