Please use this identifier to cite or link to this item: https://ah.lib.nccu.edu.tw/handle/140.119/77408
題名: Biomechanical evaluation of a new pedicle screw-based posterior dynamic stabilization device (Awesome Rod System) - a finite element analysis
作者: Chen, Chen-Sheng;Huang, Chang-Hung;Shih, Shih-Liang
施世亮
貢獻者: 神經科學研究所
關鍵詞: Posterior dynamic stabilization;Finite element model;Lumbar spine
日期: 四月-2015
上傳時間: 5-八月-2015
摘要: Background:Pedicle-screw-based posterior dynamic stabilization devices are designed to alleviate the rate of accelerated degeneration of the vertebral level adjacent to the level of spinal fusion. A new pedicle- screw-based posterior dynamic stabilization device- the Awesome Dynamic Rod System was designed with curve cuts on the rods to provide flexibility. The current study was conducted to evaluate the biomechanical properties of this new device.Methods:Finite element models were developed for the intact spine (INT), the Awesome Dynamic Rod Implanted at L4-L5 (AWE), a traditional rigid rod system implanted at L4-L5 along with an interbody cage (FUS), and the Awesome Dynamic Rod System implanted at L4-L5 along with an interbody cage as an adjunct to fusion procedures and extension of dynamic fixation to L3-L4 (AWEFUS). The models were subjected to axial loads and pure moments and evaluated by a hybrid method on range of motion (ROM)s, disc stresses, pedicle screws stresses, and facet joint contact forces.Results:FUS sustained the lowest L4-L5 ROM decrement in flexion and torsion. AWE demonstrated the lowest adjacent level ROM increment in all moments except for extension at L3-L4, and AWEFUS showed the greatest ROM increment at L2-L3. AWE demonstrated lowest adjacent segment disc stress in flexion, lateral bending and torsion at L3-L4. AWEFUS showed the highest disc stress increment in flexion, extension, and lateral bending, and the lowest disc stress decrement in torsion at L2-L3. AWE sustained greater adjacent facet joint contact forces than did FUS in extension and lateral bending at L3-L4, and AWEFUS demonstrated the greatest contact forces concentrating at L2-L3.Conclusion:The results demonstrate that the Awesome Dynamic Rod System preserved more bridged segment motion than did the traditional rigid rod fixation system except in extension. However, the Awesome Dynamic Rod System bore a greater facet joint contact force in extension. The Awesome Dynamic Rod System did protect the adjacent level of fusion segments, but led to much greater ROM, disc stresses, and facet joint contact forces increasing at the adjacent level of instrumented segments.
關聯: BMC Musculoskeletal Disorders,16:81
資料類型: article
DOI: http://dx.doi.org/10.1186/s12891-015-0538-x
Appears in Collections:期刊論文

Files in This Item:
File Description SizeFormat
s12891-015-0538-x.pdf881.93 kBAdobe PDF2View/Open
Show full item record

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.