Please use this identifier to cite or link to this item: https://ah.lib.nccu.edu.tw/handle/140.119/65240
DC FieldValueLanguage
dc.contributor應物所en_US
dc.creatorLin, Jyh-Miin ; Tsai, Shang-Yueh ; Chung, Hsiao-Wen ; Cheng, Chou-Min ; Yeh, Tzu-Chen ; Liu, Hua-Shanen_US
dc.creator蔡尚岳zh_TW
dc.date2009.12en_US
dc.date.accessioned2014-04-10T03:16:19Z-
dc.date.available2014-04-10T03:16:19Z-
dc.date.issued2014-04-10T03:16:19Z-
dc.identifier.urihttp://nccur.lib.nccu.edu.tw/handle/140.119/65240-
dc.description.abstractIntrascan subject movement in clinical MR spectroscopic examinations may result in inconsistent water suppression that distorts the metabolite signals, frame-to-frame variations in spectral phase and frequency, and consequent reductions in the signal-to-noise ratio due to destructive averaging. Frame-to-frame phase/frequency corrections, although reported to be successful in achieving constructive averaging, rely on consistent water suppression, which may be difficult in the presence of intrascan motion. In this study, motion correction using non–water-suppressed data acquisition is proposed to overcome the above difficulties. The time-domain matrix-pencil postprocessing method was used to extract water signals from the non–water-suppressed spectroscopic data, followed by phase and frequency corrections of the metabolite signals based on information obtained from the water signals. From in vivo experiments on seven healthy subjects at 3.0 T, quantification of metabolites using the unsuppressed water signal as a reference showed improved correlation with water-suppressed data acquired in the absence of motion (R2 = 0.9669; slope = 0.94). The metabolite concentrations derived using the proposed approach were in good agreement with literature values. Computer simulations under various degrees of frequency and phase variations further demonstrated robust performance of the time-domain postprocessing approach. Magn Reson Med, 2009. © 2009 Wiley-Liss, Inc.en_US
dc.format.extent1089954 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoen_US-
dc.relationMagnetic Resonance in Medicine ,62(6), 1394-1403en_US
dc.subjectnon–water suppressed MRS;in vivo single voxel spectroscopy;motion correction;spectral processing;signal restorationen_US
dc.titleQuantification of Non-Water-Suppressed MR Spectra with Correction for Motion-Induced Signal Reductionen_US
dc.typearticleen
dc.identifier.doi10.1002/mrm.22119en_US
dc.doi.urihttp://dx.doi.org/10.1002/mrm.22119 en_US
item.languageiso639-1en_US-
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.grantfulltextrestricted-
item.openairetypearticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Collections:期刊論文
Files in This Item:
File Description SizeFormat
22119.pdf1.06 MBAdobe PDF2View/Open
Show simple item record

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.