Please use this identifier to cite or link to this item: https://ah.lib.nccu.edu.tw/handle/140.119/65801
DC FieldValueLanguage
dc.contributor應物所en_US
dc.creator蔡尚岳zh_TW
dc.creatorTsai, Shang-Yuehen_US
dc.creatorLin,Fa-Hsuan;Tsai,Shang-Yueh ;Ricardo Otazo;Arvind Caprihan;Lawrence L. Wald;John W. Belliveau-
dc.date2007.02en_US
dc.date.accessioned2014-05-01T09:47:18Z-
dc.date.available2014-05-01T09:47:18Z-
dc.date.issued2014-05-01T09:47:18Z-
dc.identifier.urihttp://nccur.lib.nccu.edu.tw/handle/140.119/65801-
dc.description.abstractMagnetic resonance spectroscopic imaging (MRSI) provides spatially resolved metabolite information that is invaluable for both neuroscience studies and clinical applications. However, lengthy data acquisition times, which are a result of time-consuming phase encoding, represent a major challenge for MRSI. Fast MRSI pulse sequences that use echo-planar readout gradients, such as proton echo-planar spectroscopic imaging (PEPSI), are capable of fast spectral-spatial encoding and thus enable acceleration of image acquisition times. Combining PEPSI with recent advances in parallel MRI utilizing RF coil arrays can further accelerate MRSI data acquisition. Here we investigate the feasibility of ultrafast spectroscopic imaging at high field (3T and 4T) by combining PEPSI with sensitivity-encoded (SENSE) MRI using eight-channel head coil arrays. We show that the acquisition of single-average SENSE-PEPSI data at a short TE (15 ms) can be accelerated to 32 s or less, depending on the field strength, to obtain metabolic images of choline (Cho), creatine (Cre), N-acetyl-aspartate (NAA), and J-coupled metabolites (e.g., glutamate (Glu) and inositol (Ino)) with acceptable spectral quality and localization. The experimentally measured reductions in signal-to-noise ratio (SNR) and Cramer-Rao lower bounds (CRLBs) of metabolite resonances were well explained by both the g-factor and reduced measurement times. Thus, this technology is a promising means of reducing the scan times of 3D acquisitions and time-resolved 2D measurements. Magn Reson Med 57:249–257, 2007. © 2007 Wiley-Liss, Inc.en_US
dc.format.extent1077797 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoen_US-
dc.relationMagn Reson Med, 57(2), 249-257en_US
dc.subjectSENSE;PEPSI;parallel MRI;spectroscopic imaging;MRSen_US
dc.titleSensitivity-encoded (SENSE) Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) in Human Brainen_US
dc.typearticleen
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en_US-
item.grantfulltextrestricted-
item.openairetypearticle-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
Appears in Collections:期刊論文
Files in This Item:
File Description SizeFormat
21119.pdf1.05 MBAdobe PDF2View/Open
Show simple item record

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.