Publications-Periodical Articles

Article View/Open

Publication Export

Google ScholarTM

NCCU Library

Citation Infomation

Related Publications in TAIR

題名 Simultaneous multi-slice inverse imaging of the human brain
作者 蔡尚岳
Hsu, Yi-Cheng
Chu, Ying-Hua
Tsai, Shang-Yueh
Kuo, Wen-Jui
Chang, Chun-Yuan
貢獻者 應物所
日期 2017-12
上傳時間 18-Apr-2018 14:45:31 (UTC+8)
摘要 (BOLD) signals with high sensitivity and specificity. Here we propose a novel method: simultaneous multi-slice inverse imaging (SMS-InI) — a combination of simultaneous multi-slice excitation, simultaneous echo refocusing (SER), blipped controlled aliasing in parallel imaging echo-planar imaging (EPI), and regularized image reconstruction. Using a 32-channel head coil array on a 3 T scanner, SMS-InI achieves nominal isotropic 5-mm spatial resolution and 10 Hz sampling rate at the whole-brain level. Compared with traditional inverse imaging, we found that SMS-InI has higher spatial resolution with lower signal leakage and higher time-domain signal-to-noise ratio with the optimized regularization parameter in the reconstruction. SMS-InI achieved higher effective resolution and higher detection power in detecting visual cortex activity than InI. SMS-InI also detected subcortical fMRI signals with the similar sensitivity and localization accuracy like EPI. The spatiotemporal resolution of SMS-InI was used to reveal that presenting visual stimuli with 0.2 s latency between left and right visual hemifield led to 0.2 s relative hemodynamic response latency between the left and right visual cortices. Together, these results indicate that SMS-InI is a useful tool in measuring cortical and subcortical hemodynamic responses with high spatiotemporal resolution.
關聯 Scientific Reports, 2017; 7: 17019.
資料類型 article
DOI https://dx.doi.org/10.1038%2Fs41598-017-16976-0
dc.contributor 應物所zh_Tw
dc.creator (作者) 蔡尚岳zh_TW
dc.creator (作者) Hsu, Yi-Chengen_US
dc.creator (作者) Chu, Ying-Huaen_US
dc.creator (作者) Tsai, Shang-Yuehen_US
dc.creator (作者) Kuo, Wen-Juien_US
dc.creator (作者) Chang, Chun-Yuanen_US
dc.date (日期) 2017-12
dc.date.accessioned 18-Apr-2018 14:45:31 (UTC+8)-
dc.date.available 18-Apr-2018 14:45:31 (UTC+8)-
dc.date.issued (上傳時間) 18-Apr-2018 14:45:31 (UTC+8)-
dc.identifier.uri (URI) http://nccur.lib.nccu.edu.tw/handle/140.119/116900-
dc.description.abstract (摘要) (BOLD) signals with high sensitivity and specificity. Here we propose a novel method: simultaneous multi-slice inverse imaging (SMS-InI) — a combination of simultaneous multi-slice excitation, simultaneous echo refocusing (SER), blipped controlled aliasing in parallel imaging echo-planar imaging (EPI), and regularized image reconstruction. Using a 32-channel head coil array on a 3 T scanner, SMS-InI achieves nominal isotropic 5-mm spatial resolution and 10 Hz sampling rate at the whole-brain level. Compared with traditional inverse imaging, we found that SMS-InI has higher spatial resolution with lower signal leakage and higher time-domain signal-to-noise ratio with the optimized regularization parameter in the reconstruction. SMS-InI achieved higher effective resolution and higher detection power in detecting visual cortex activity than InI. SMS-InI also detected subcortical fMRI signals with the similar sensitivity and localization accuracy like EPI. The spatiotemporal resolution of SMS-InI was used to reveal that presenting visual stimuli with 0.2 s latency between left and right visual hemifield led to 0.2 s relative hemodynamic response latency between the left and right visual cortices. Together, these results indicate that SMS-InI is a useful tool in measuring cortical and subcortical hemodynamic responses with high spatiotemporal resolution.en_US
dc.format.extent 3411915 bytes-
dc.format.mimetype application/pdf-
dc.relation (關聯) Scientific Reports, 2017; 7: 17019.
dc.title (題名) Simultaneous multi-slice inverse imaging of the human brainen_US
dc.type (資料類型) article
dc.identifier.doi (DOI) 10.1038/s41598-017-16976-0
dc.doi.uri (DOI) https://dx.doi.org/10.1038%2Fs41598-017-16976-0