Publications-Periodical Articles

Article View/Open

Publication Export

Google ScholarTM

NCCU Library

Citation Infomation

Related Publications in TAIR

題名 Septic Arthritis Modeling Using Sonographic Fusion with Attention and Selective Transformation: A Preliminary Study
作者 羅崇銘
Lo, Chung-Ming;Lai, Kuo-Lung
貢獻者 圖檔所
關鍵詞 Knee; Septic arthritis; Vision transformer; Convolutional block attention module
日期 2024-09
上傳時間 24-Feb-2025 15:55:39 (UTC+8)
摘要 Conventionally diagnosing septic arthritis relies on detecting the causal pathogens in samples of synovial fluid, synovium, or blood. However, isolating these pathogens through cultures takes several days, thus delaying both diagnosis and treatment. Establishing a quantitative classification model from ultrasound images for rapid septic arthritis diagnosis is mandatory. For the study, a database composed of 342 images of non-septic arthritis and 168 images of septic arthritis produced by grayscale (GS) and power Doppler (PD) ultrasound was constructed. In the proposed architecture of fusion with attention and selective transformation (FAST), both groups of images were combined in a vision transformer (ViT) with the convolutional block attention module, which incorporates spatial, modality, and channel features. Fivefold cross-validation was applied to evaluate the generalized ability. The FAST architecture achieved the accuracy, sensitivity, specificity, and area under the curve (AUC) of 86.33%, 80.66%, 90.25%, and 0.92, respectively. These performances were higher than using conventional ViT (82.14%) and significantly better than using one modality alone (GS 73.88%, PD 72.02%), with the p-value being less than 0.01. Through the integration of multi-modality and the extraction of multiple channel features, the established model provided promising accuracy and AUC in septic arthritis classification. The end-to-end learning of ultrasound features can provide both rapid and objective assessment suggestions for future clinic use.
關聯 Journal of Imaging Informatics in Medicine, Vol.38, No.2, pp.1028-1039
資料類型 article
DOI https://doi.org/10.1007/s10278-024-01259-8
dc.contributor 圖檔所-
dc.creator (作者) 羅崇銘-
dc.creator (作者) Lo, Chung-Ming;Lai, Kuo-Lung-
dc.date (日期) 2024-09-
dc.date.accessioned 24-Feb-2025 15:55:39 (UTC+8)-
dc.date.available 24-Feb-2025 15:55:39 (UTC+8)-
dc.date.issued (上傳時間) 24-Feb-2025 15:55:39 (UTC+8)-
dc.identifier.uri (URI) https://nccur.lib.nccu.edu.tw/handle/140.119/155799-
dc.description.abstract (摘要) Conventionally diagnosing septic arthritis relies on detecting the causal pathogens in samples of synovial fluid, synovium, or blood. However, isolating these pathogens through cultures takes several days, thus delaying both diagnosis and treatment. Establishing a quantitative classification model from ultrasound images for rapid septic arthritis diagnosis is mandatory. For the study, a database composed of 342 images of non-septic arthritis and 168 images of septic arthritis produced by grayscale (GS) and power Doppler (PD) ultrasound was constructed. In the proposed architecture of fusion with attention and selective transformation (FAST), both groups of images were combined in a vision transformer (ViT) with the convolutional block attention module, which incorporates spatial, modality, and channel features. Fivefold cross-validation was applied to evaluate the generalized ability. The FAST architecture achieved the accuracy, sensitivity, specificity, and area under the curve (AUC) of 86.33%, 80.66%, 90.25%, and 0.92, respectively. These performances were higher than using conventional ViT (82.14%) and significantly better than using one modality alone (GS 73.88%, PD 72.02%), with the p-value being less than 0.01. Through the integration of multi-modality and the extraction of multiple channel features, the established model provided promising accuracy and AUC in septic arthritis classification. The end-to-end learning of ultrasound features can provide both rapid and objective assessment suggestions for future clinic use.-
dc.format.extent 106 bytes-
dc.format.mimetype text/html-
dc.relation (關聯) Journal of Imaging Informatics in Medicine, Vol.38, No.2, pp.1028-1039-
dc.subject (關鍵詞) Knee; Septic arthritis; Vision transformer; Convolutional block attention module-
dc.title (題名) Septic Arthritis Modeling Using Sonographic Fusion with Attention and Selective Transformation: A Preliminary Study-
dc.type (資料類型) article-
dc.identifier.doi (DOI) 10.1007/s10278-024-01259-8-
dc.doi.uri (DOI) https://doi.org/10.1007/s10278-024-01259-8-