學術產出-Periodical Articles

Article View/Open

Publication Export

Google ScholarTM

政大圖書館

Citation Infomation

  • No doi shows Citation Infomation
題名 Accelerated Proton-Echo-Planar-Spectroscopic-Imaging using GRAPPA with a 32-Channel Phase Array Coil
作者 蔡尚岳
Tsai, Shang-Yueh ; Otazo, Ricardo ; Posse, Stefan ; Lin, Yi-Ru ; Chung, Hsiao-Wen ; Wald, Lawrence L. ; Wiggins, Graham C. ; Lin, Fa-Hsuan
貢獻者 應物所
關鍵詞 proton echo planar spectroscopic imaging; PEPSI; MR spectroscopic imaging; parallel MRI; 32
日期 2008.04
上傳時間 11-Feb-2014 14:02:20 (UTC+8)
摘要 Parallel imaging has been demonstrated to reduce the encoding time of MR spectroscopic imaging (MRSI). Here we investigate up to 5-fold acceleration of 2D proton echo planar spectroscopic imaging (PEPSI) at 3T using generalized autocalibrating partial parallel acquisition (GRAPPA) with a 32-channel coil array, 1.5 cm3 voxel size, TR/TE of 15/2000 ms, and 2.1 Hz spectral resolution. Compared to an 8-channel array, the smaller RF coil elements in this 32-channel array provided a 3.1-fold and 2.8-fold increase in signal-to-noise ratio (SNR) in the peripheral region and the central region, respectively, and more spatial modulated information. Comparison of sensitivity-encoding (SENSE) and GRAPPA reconstruction using an 8-channel array showed that both methods yielded similar quantitative metabolite measures (P > 0.1). Concentration values of N-acetyl-aspartate (NAA), total creatine (tCr), choline (Cho), myo-inositol (mI), and the sum of glutamate and glutamine (Glx) for both methods were consistent with previous studies. Using the 32-channel array coil the mean Cramer–Rao lower bounds (CRLB) were less than 8% for NAA, tCr, and Cho and less than 15% for mI and Glx at 2-fold acceleration. At 4-fold acceleration the mean CRLB for NAA, tCr, and Cho was less than 11%. In conclusion, the use of a 32-channel coil array and GRAPPA reconstruction can significantly reduce the measurement time for mapping brain metabolites. Magn Reson Med 59:989–998, 2008. © 2008 Wiley-Liss, Inc.
關聯 Magn Reson Med, 59(5), 989-998
資料類型 article
dc.contributor 應物所en_US
dc.creator (作者) 蔡尚岳zh_TW
dc.creator (作者) Tsai, Shang-Yueh ; Otazo, Ricardo ; Posse, Stefan ; Lin, Yi-Ru ; Chung, Hsiao-Wen ; Wald, Lawrence L. ; Wiggins, Graham C. ; Lin, Fa-Hsuanen_US
dc.date (日期) 2008.04en_US
dc.date.accessioned 11-Feb-2014 14:02:20 (UTC+8)-
dc.date.available 11-Feb-2014 14:02:20 (UTC+8)-
dc.date.issued (上傳時間) 11-Feb-2014 14:02:20 (UTC+8)-
dc.identifier.uri (URI) http://nccur.lib.nccu.edu.tw/handle/140.119/63785-
dc.description.abstract (摘要) Parallel imaging has been demonstrated to reduce the encoding time of MR spectroscopic imaging (MRSI). Here we investigate up to 5-fold acceleration of 2D proton echo planar spectroscopic imaging (PEPSI) at 3T using generalized autocalibrating partial parallel acquisition (GRAPPA) with a 32-channel coil array, 1.5 cm3 voxel size, TR/TE of 15/2000 ms, and 2.1 Hz spectral resolution. Compared to an 8-channel array, the smaller RF coil elements in this 32-channel array provided a 3.1-fold and 2.8-fold increase in signal-to-noise ratio (SNR) in the peripheral region and the central region, respectively, and more spatial modulated information. Comparison of sensitivity-encoding (SENSE) and GRAPPA reconstruction using an 8-channel array showed that both methods yielded similar quantitative metabolite measures (P > 0.1). Concentration values of N-acetyl-aspartate (NAA), total creatine (tCr), choline (Cho), myo-inositol (mI), and the sum of glutamate and glutamine (Glx) for both methods were consistent with previous studies. Using the 32-channel array coil the mean Cramer–Rao lower bounds (CRLB) were less than 8% for NAA, tCr, and Cho and less than 15% for mI and Glx at 2-fold acceleration. At 4-fold acceleration the mean CRLB for NAA, tCr, and Cho was less than 11%. In conclusion, the use of a 32-channel coil array and GRAPPA reconstruction can significantly reduce the measurement time for mapping brain metabolites. Magn Reson Med 59:989–998, 2008. © 2008 Wiley-Liss, Inc.en_US
dc.format.extent 1150044 bytes-
dc.format.mimetype application/pdf-
dc.language.iso en_US-
dc.relation (關聯) Magn Reson Med, 59(5), 989-998en_US
dc.subject (關鍵詞) proton echo planar spectroscopic imaging; PEPSI; MR spectroscopic imaging; parallel MRI; 32en_US
dc.title (題名) Accelerated Proton-Echo-Planar-Spectroscopic-Imaging using GRAPPA with a 32-Channel Phase Array Coilen_US
dc.type (資料類型) articleen