Publications-Periodical Articles

Article View/Open

Publication Export

Google ScholarTM

NCCU Library

Citation Infomation

Related Publications in TAIR

題名 Quantification of Non-Water-Suppressed MR Spectra with Correction for Motion-Induced Signal Reduction
作者 Lin, Jyh-Miin ; Tsai, Shang-Yueh ; Chung, Hsiao-Wen ; Cheng, Chou-Min ; Yeh, Tzu-Chen ; Liu, Hua-Shan
蔡尚岳
貢獻者 應物所
關鍵詞 non–water suppressed MRS;in vivo single voxel spectroscopy;motion correction;spectral processing;signal restoration
日期 2009.12
上傳時間 10-Apr-2014 11:16:19 (UTC+8)
摘要 Intrascan subject movement in clinical MR spectroscopic examinations may result in inconsistent water suppression that distorts the metabolite signals, frame-to-frame variations in spectral phase and frequency, and consequent reductions in the signal-to-noise ratio due to destructive averaging. Frame-to-frame phase/frequency corrections, although reported to be successful in achieving constructive averaging, rely on consistent water suppression, which may be difficult in the presence of intrascan motion. In this study, motion correction using non–water-suppressed data acquisition is proposed to overcome the above difficulties. The time-domain matrix-pencil postprocessing method was used to extract water signals from the non–water-suppressed spectroscopic data, followed by phase and frequency corrections of the metabolite signals based on information obtained from the water signals. From in vivo experiments on seven healthy subjects at 3.0 T, quantification of metabolites using the unsuppressed water signal as a reference showed improved correlation with water-suppressed data acquired in the absence of motion (R2 = 0.9669; slope = 0.94). The metabolite concentrations derived using the proposed approach were in good agreement with literature values. Computer simulations under various degrees of frequency and phase variations further demonstrated robust performance of the time-domain postprocessing approach. Magn Reson Med, 2009. © 2009 Wiley-Liss, Inc.
關聯 Magnetic Resonance in Medicine ,62(6), 1394-1403
資料類型 article
DOI http://dx.doi.org/10.1002/mrm.22119
dc.contributor 應物所en_US
dc.creator (作者) Lin, Jyh-Miin ; Tsai, Shang-Yueh ; Chung, Hsiao-Wen ; Cheng, Chou-Min ; Yeh, Tzu-Chen ; Liu, Hua-Shanen_US
dc.creator (作者) 蔡尚岳zh_TW
dc.date (日期) 2009.12en_US
dc.date.accessioned 10-Apr-2014 11:16:19 (UTC+8)-
dc.date.available 10-Apr-2014 11:16:19 (UTC+8)-
dc.date.issued (上傳時間) 10-Apr-2014 11:16:19 (UTC+8)-
dc.identifier.uri (URI) http://nccur.lib.nccu.edu.tw/handle/140.119/65240-
dc.description.abstract (摘要) Intrascan subject movement in clinical MR spectroscopic examinations may result in inconsistent water suppression that distorts the metabolite signals, frame-to-frame variations in spectral phase and frequency, and consequent reductions in the signal-to-noise ratio due to destructive averaging. Frame-to-frame phase/frequency corrections, although reported to be successful in achieving constructive averaging, rely on consistent water suppression, which may be difficult in the presence of intrascan motion. In this study, motion correction using non–water-suppressed data acquisition is proposed to overcome the above difficulties. The time-domain matrix-pencil postprocessing method was used to extract water signals from the non–water-suppressed spectroscopic data, followed by phase and frequency corrections of the metabolite signals based on information obtained from the water signals. From in vivo experiments on seven healthy subjects at 3.0 T, quantification of metabolites using the unsuppressed water signal as a reference showed improved correlation with water-suppressed data acquired in the absence of motion (R2 = 0.9669; slope = 0.94). The metabolite concentrations derived using the proposed approach were in good agreement with literature values. Computer simulations under various degrees of frequency and phase variations further demonstrated robust performance of the time-domain postprocessing approach. Magn Reson Med, 2009. © 2009 Wiley-Liss, Inc.en_US
dc.format.extent 1089954 bytes-
dc.format.mimetype application/pdf-
dc.language.iso en_US-
dc.relation (關聯) Magnetic Resonance in Medicine ,62(6), 1394-1403en_US
dc.subject (關鍵詞) non–water suppressed MRS;in vivo single voxel spectroscopy;motion correction;spectral processing;signal restorationen_US
dc.title (題名) Quantification of Non-Water-Suppressed MR Spectra with Correction for Motion-Induced Signal Reductionen_US
dc.type (資料類型) articleen
dc.identifier.doi (DOI) 10.1002/mrm.22119en_US
dc.doi.uri (DOI) http://dx.doi.org/10.1002/mrm.22119 en_US