學術產出-Periodical Articles
Article View/Open
Publication Export
-
題名 Comparison of arterial spin labeling and first-pass dynamic contrast-enhanced MR imaging in the assessment of pulmonary perfusion in humans: The inflow spin-tracer saturation effect 作者 蔡尚岳
Lin,Yi-Ru ;Wu,Ming-Ting ;Huang,Teng-Yi ;Tsai,Shang-Yueh ;Chung,Hsiao-Wen ;Vu M. Mai貢獻者 應物所 日期 2004.11 上傳時間 1-May-2014 17:46:41 (UTC+8) 摘要 The flow-sensitive alternating inversion recovery (FAIR) and the first-pass dynamic contrast-enhanced MR imaging (CE-MRI) techniques have both been shown to be effective in the assessment of human pulmonary perfusion. However, no comprehensive comparison of the measurements by these two methods has been reported. In this study, healthy adults were recruited, with FAIR and CE-MRI performed for an estimation of the relative pulmonary blood flow (rPBF). Regions of interest were encircled from the right and left lungs, with right-to-left rPBF ratios calculated. Results indicated that, on posterior coronal slices, the rPBF ratios obtained with the FAIR technique agreed well with CE-MRI measurements (mean difference = −0.02, intraclass correlation coefficient RI = 0.78, 95% confidence interval = [0.67, 0.86]). On middle coronal slices, however, FAIR showed a substantially lower rPBF by up to 43% in the right lung compared with CE-MRI (mean difference = −0.38, RI = 0.34, 95% confidence interval = [−0.09, 0.68]). The location-dependent discrepancy between measurements by FAIR and CE-MRI methods is attributed to tracer saturation effects of arterial inflow when the middle coronal slice contains the in-plane-oriented right pulmonary artery, whereas the left lung rPBF is less affected due to oblique orientation of the left pulmonary artery. Intrasequence comparison on additional subjects using FAIR at different slice orientations supported the above hypothesis. It is concluded that FAIR imaging for pulmonary perfusion in the coronal plane provides equivalent rPBF information with CE-MRI only in the absence of tracer saturation effects; hence, FAIR should be carefully exercised to avoid misleading interpretations. Magn Reson Med 52:1291–1301, 2004. © 2004 Wiley-Liss, Inc. 關聯 Magn Reson Med, 52(6), 1291-1301 資料類型 article dc.contributor 應物所 en_US dc.creator (作者) 蔡尚岳 zh_TW dc.creator (作者) Lin,Yi-Ru ;Wu,Ming-Ting ;Huang,Teng-Yi ;Tsai,Shang-Yueh ;Chung,Hsiao-Wen ;Vu M. Mai en_US dc.date (日期) 2004.11 en_US dc.date.accessioned 1-May-2014 17:46:41 (UTC+8) - dc.date.available 1-May-2014 17:46:41 (UTC+8) - dc.date.issued (上傳時間) 1-May-2014 17:46:41 (UTC+8) - dc.identifier.uri (URI) http://nccur.lib.nccu.edu.tw/handle/140.119/65798 - dc.description.abstract (摘要) The flow-sensitive alternating inversion recovery (FAIR) and the first-pass dynamic contrast-enhanced MR imaging (CE-MRI) techniques have both been shown to be effective in the assessment of human pulmonary perfusion. However, no comprehensive comparison of the measurements by these two methods has been reported. In this study, healthy adults were recruited, with FAIR and CE-MRI performed for an estimation of the relative pulmonary blood flow (rPBF). Regions of interest were encircled from the right and left lungs, with right-to-left rPBF ratios calculated. Results indicated that, on posterior coronal slices, the rPBF ratios obtained with the FAIR technique agreed well with CE-MRI measurements (mean difference = −0.02, intraclass correlation coefficient RI = 0.78, 95% confidence interval = [0.67, 0.86]). On middle coronal slices, however, FAIR showed a substantially lower rPBF by up to 43% in the right lung compared with CE-MRI (mean difference = −0.38, RI = 0.34, 95% confidence interval = [−0.09, 0.68]). The location-dependent discrepancy between measurements by FAIR and CE-MRI methods is attributed to tracer saturation effects of arterial inflow when the middle coronal slice contains the in-plane-oriented right pulmonary artery, whereas the left lung rPBF is less affected due to oblique orientation of the left pulmonary artery. Intrasequence comparison on additional subjects using FAIR at different slice orientations supported the above hypothesis. It is concluded that FAIR imaging for pulmonary perfusion in the coronal plane provides equivalent rPBF information with CE-MRI only in the absence of tracer saturation effects; hence, FAIR should be carefully exercised to avoid misleading interpretations. Magn Reson Med 52:1291–1301, 2004. © 2004 Wiley-Liss, Inc. en_US dc.format.extent 761242 bytes - dc.format.mimetype application/pdf - dc.language.iso en_US - dc.relation (關聯) Magn Reson Med, 52(6), 1291-1301 en_US dc.title (題名) Comparison of arterial spin labeling and first-pass dynamic contrast-enhanced MR imaging in the assessment of pulmonary perfusion in humans: The inflow spin-tracer saturation effect en_US dc.type (資料類型) article en