學術產出-Periodical Articles

Article View/Open

Publication Export

Google ScholarTM

政大圖書館

Citation Infomation

題名 Effects of cord pretension and stiffness of the Dynesys system spacer on the biomechanics of spinal decompression- a finite element study
作者 施世亮
Shih, Shih-Liang;Liu, Chien-Lin;Huang, Li-Ying;Huang, Chang-Hung;Chen, Chen-Sheng
貢獻者 神科所
關鍵詞 Adjacent disc;Decompression;Dynesys;Cord pretension;Spacer;Finite element analysis
日期 2013.06
上傳時間 12-Aug-2014 15:05:29 (UTC+8)
摘要 Background: The Dynesys system provides stability for destabilized spines while preserving segmental motion. However, clinical studies have demonstrated that the Dynesys system does not prevent adjacent segment disease. Moreover, biomechanical studies have revealed that the stiffness of the Dynesys system is comparable to rigid fixation. Our previous studies showed that adjusting the cord pretension of the Dynesys system alleviates stress on the adjacent level during flexion. We also demonstrated that altering the stiffness of Dynesys system spacers can alleviate stress on the adjacent level during extension of the intact spine. In the present study, we hypothesized that omitting the cord preload and changing the stiffness of the Dynesys system spacers would abate stress shielding on adjacent spinal segments. Methods: Finite element models were developed for - intact spine (INT), facetectomy and laminectomy at L3-4 (DEC), intact spine with Dynesys system (IntDyWL), decompressed spine with Dynesys system (DecDyWL), decompressed spine with Dynesys system without cord preload (DecDyNL), and decompressed spine with Dynesys system assembled using spacers that were 0.8 times the standard diameter without cord pretension (DecDyNL0.8). These models were subjected to hybrid control for flexion, extension, axial rotation; and lateral bending. Results: The greatest decreases in range of motion (ROM) at the L3-4 level occurred for axial rotation and lateral bending in the IntDyWL model and for flexion and extension in the DecDyWL model. The greatest decreases in disc stress occurred for extension and lateral bending in the IntDyWL model and for flexion in the DecDyWL model. The greatest decreases in facet contact force occurred for extension and lateral bending in the DecDyNL model and for axial rotation in the DecDyWL model. The greatest increases in ROMs at L2-3 level occurred for flexion, axial rotation and lateral bending in IntDyWL model and for extension in the DecDyNL model. The greatest increases in disc stress occurred for flexion, axial rotation and lateral bending in the IntDyWL model and for extension in the DecDyNL model. The greatest increases in facet contact force occurred for extension and lateral bending in the DecDyNL model and for axial rotation in the IntDyWL model. Conclusions: The results reveals that removing the Dynesys system cord pretension attenuates the ROMs, disc stress, and facet joint contact forces at adjacent levels during flexion and axial rotation. Removing cord pretension together with softening spacers abates stress shielding for adjacent segment during four different moments, and it provides enough security while not jeopardizes the stability of spine during axial rotation.
關聯 BioMed Central Musculoskeletal Disorder, 14(191), 1-10
資料類型 article
DOI http://dx.doi.org/10.1186/1471-2474-14-191
dc.contributor 神科所en_US
dc.creator (作者) 施世亮zh_TW
dc.creator (作者) Shih, Shih-Liang;Liu, Chien-Lin;Huang, Li-Ying;Huang, Chang-Hung;Chen, Chen-Shengen_US
dc.date (日期) 2013.06en_US
dc.date.accessioned 12-Aug-2014 15:05:29 (UTC+8)-
dc.date.available 12-Aug-2014 15:05:29 (UTC+8)-
dc.date.issued (上傳時間) 12-Aug-2014 15:05:29 (UTC+8)-
dc.identifier.uri (URI) http://nccur.lib.nccu.edu.tw/handle/140.119/68610-
dc.description.abstract (摘要) Background: The Dynesys system provides stability for destabilized spines while preserving segmental motion. However, clinical studies have demonstrated that the Dynesys system does not prevent adjacent segment disease. Moreover, biomechanical studies have revealed that the stiffness of the Dynesys system is comparable to rigid fixation. Our previous studies showed that adjusting the cord pretension of the Dynesys system alleviates stress on the adjacent level during flexion. We also demonstrated that altering the stiffness of Dynesys system spacers can alleviate stress on the adjacent level during extension of the intact spine. In the present study, we hypothesized that omitting the cord preload and changing the stiffness of the Dynesys system spacers would abate stress shielding on adjacent spinal segments. Methods: Finite element models were developed for - intact spine (INT), facetectomy and laminectomy at L3-4 (DEC), intact spine with Dynesys system (IntDyWL), decompressed spine with Dynesys system (DecDyWL), decompressed spine with Dynesys system without cord preload (DecDyNL), and decompressed spine with Dynesys system assembled using spacers that were 0.8 times the standard diameter without cord pretension (DecDyNL0.8). These models were subjected to hybrid control for flexion, extension, axial rotation; and lateral bending. Results: The greatest decreases in range of motion (ROM) at the L3-4 level occurred for axial rotation and lateral bending in the IntDyWL model and for flexion and extension in the DecDyWL model. The greatest decreases in disc stress occurred for extension and lateral bending in the IntDyWL model and for flexion in the DecDyWL model. The greatest decreases in facet contact force occurred for extension and lateral bending in the DecDyNL model and for axial rotation in the DecDyWL model. The greatest increases in ROMs at L2-3 level occurred for flexion, axial rotation and lateral bending in IntDyWL model and for extension in the DecDyNL model. The greatest increases in disc stress occurred for flexion, axial rotation and lateral bending in the IntDyWL model and for extension in the DecDyNL model. The greatest increases in facet contact force occurred for extension and lateral bending in the DecDyNL model and for axial rotation in the IntDyWL model. Conclusions: The results reveals that removing the Dynesys system cord pretension attenuates the ROMs, disc stress, and facet joint contact forces at adjacent levels during flexion and axial rotation. Removing cord pretension together with softening spacers abates stress shielding for adjacent segment during four different moments, and it provides enough security while not jeopardizes the stability of spine during axial rotation.en_US
dc.format.extent 2605738 bytes-
dc.format.mimetype application/pdf-
dc.language.iso en_US-
dc.relation (關聯) BioMed Central Musculoskeletal Disorder, 14(191), 1-10en_US
dc.subject (關鍵詞) Adjacent disc;Decompression;Dynesys;Cord pretension;Spacer;Finite element analysisen_US
dc.title (題名) Effects of cord pretension and stiffness of the Dynesys system spacer on the biomechanics of spinal decompression- a finite element studyen_US
dc.type (資料類型) articleen
dc.identifier.doi (DOI) 10.1186/1471-2474-14-191en_US
dc.doi.uri (DOI) http://dx.doi.org/10.1186/1471-2474-14-191en_US