學術產出-Periodical Articles
Article View/Open
Publication Export
-
題名 Hippocampal dosimetry correlates with the change in neurocognitive function after hippocampal sparing during whole brain radiotherapy: a prospective study. 作者 楊啟正
Tsai, Ping-Fang
Yang, Chi-Cheng
Chuang, Chi-Cheng
Huang, Ting-Yi
Wu, Yi-Ming
Pai, Ping-Ching
Tseng, Chen-Kan
Wu, Tung-Ho
Shen, Yi-Liang
Lin, Shinn-Yn貢獻者 心理系 關鍵詞 Brain metastasis; Whole brain radiotherapy; Neurocognitive functions; Hippocampus; Hippocampus sparing during whole brain radiotherapy – Hippocampal dosimetry 日期 2015-12 上傳時間 6-Sep-2017 16:29:43 (UTC+8) 摘要 Background : Whole brain radiotherapy (WBRT) has been the treatment of choice for patients with brain metastases. However, change/decline of neurocognitive functions (NCFs) resulting from impaired hippocampal neurogenesis might occur after WBRT. It is reported that conformal hippocampal sparing would provide the preservation of NCFs. Our study aims to investigate the hippocampal dosimetry and to demonstrate the correlation between hippocampal dosimetry and neurocognitive outcomes in patients receiving hippocampal sparing during WBRT (HS-WBRT). Methods : Forty prospectively recruited cancer patients underwent HS-WBRT for therapeutic or prophylactic purposes. Before receiving HS-WBRT, all participants received a battery of baseline neurocognitive assessment, including memory, executive functions and psychomotor speed. The follow-up neurocognitive assessment at 4 months after HS-WBRT was also performed. For the delivery of HS-WBRT, Volumetric Modulated Arc Therapy (VMAT) with two full arcs and two non-coplanar partial arcs was employed. For each treatment planning, dose volume histograms were generated for left hippocampus, right hippocampus, and the composite hippocampal structure respectively. Biologically equivalent doses in 2-Gy fractions (EQD2) assuming an alpha/beta ratio of 2 Gy were computed. To perform analyses addressing the correlation between hippocampal dosimetry and the change in scores of NCFs, pre- and post-HS-WBRT neurocognitive assessments were available in 24 patients in this study. 關聯 Radiation Oncology, Vol.10, pp.253-263 資料類型 article DOI https://doi.org/10.1186/s13014-015-0562-x dc.contributor 心理系 zh_TW dc.creator (作者) 楊啟正 zh_TW dc.creator (作者) Tsai, Ping-Fang en_US dc.creator (作者) Yang, Chi-Cheng en_US dc.creator (作者) Chuang, Chi-Cheng en_US dc.creator (作者) Huang, Ting-Yi en_US dc.creator (作者) Wu, Yi-Ming en_US dc.creator (作者) Pai, Ping-Ching en_US dc.creator (作者) Tseng, Chen-Kan en_US dc.creator (作者) Wu, Tung-Ho en_US dc.creator (作者) Shen, Yi-Liang en_US dc.creator (作者) Lin, Shinn-Yn en_US dc.date (日期) 2015-12 dc.date.accessioned 6-Sep-2017 16:29:43 (UTC+8) - dc.date.available 6-Sep-2017 16:29:43 (UTC+8) - dc.date.issued (上傳時間) 6-Sep-2017 16:29:43 (UTC+8) - dc.identifier.uri (URI) http://nccur.lib.nccu.edu.tw/handle/140.119/112532 - dc.description.abstract (摘要) Background : Whole brain radiotherapy (WBRT) has been the treatment of choice for patients with brain metastases. However, change/decline of neurocognitive functions (NCFs) resulting from impaired hippocampal neurogenesis might occur after WBRT. It is reported that conformal hippocampal sparing would provide the preservation of NCFs. Our study aims to investigate the hippocampal dosimetry and to demonstrate the correlation between hippocampal dosimetry and neurocognitive outcomes in patients receiving hippocampal sparing during WBRT (HS-WBRT). Methods : Forty prospectively recruited cancer patients underwent HS-WBRT for therapeutic or prophylactic purposes. Before receiving HS-WBRT, all participants received a battery of baseline neurocognitive assessment, including memory, executive functions and psychomotor speed. The follow-up neurocognitive assessment at 4 months after HS-WBRT was also performed. For the delivery of HS-WBRT, Volumetric Modulated Arc Therapy (VMAT) with two full arcs and two non-coplanar partial arcs was employed. For each treatment planning, dose volume histograms were generated for left hippocampus, right hippocampus, and the composite hippocampal structure respectively. Biologically equivalent doses in 2-Gy fractions (EQD2) assuming an alpha/beta ratio of 2 Gy were computed. To perform analyses addressing the correlation between hippocampal dosimetry and the change in scores of NCFs, pre- and post-HS-WBRT neurocognitive assessments were available in 24 patients in this study. en_US dc.format.extent 1959454 bytes - dc.format.mimetype application/pdf - dc.relation (關聯) Radiation Oncology, Vol.10, pp.253-263 en_US dc.subject (關鍵詞) Brain metastasis; Whole brain radiotherapy; Neurocognitive functions; Hippocampus; Hippocampus sparing during whole brain radiotherapy – Hippocampal dosimetry en_US dc.title (題名) Hippocampal dosimetry correlates with the change in neurocognitive function after hippocampal sparing during whole brain radiotherapy: a prospective study. en_US dc.type (資料類型) article dc.identifier.doi (DOI) 10.1186/s13014-015-0562-x dc.doi.uri (DOI) https://doi.org/10.1186/s13014-015-0562-x