題名 Accelerated Short-TE 3D Proton Echo-Planar Spectroscopic Imaging using 2D-SENSE with a 32-Channel Array Coil
作者 Otazo, Ricardo ; Tsai, Shang-Yueh ; Lin, Fa-Hsuan ; Posse, Stefan
蔡尚岳
貢獻者 應物所
關鍵詞 echo-planar spectroscopic imaging;parallel imaging;SENSE;regularization;large array coil
日期 2007.12
上傳時間 10-Apr-2014 11:16:56 (UTC+8)
摘要 MR spectroscopic imaging (MRSI) with whole brain coverage in clinically feasible acquisition times still remains a major challenge. A combination of MRSI with parallel imaging has shown promise to reduce the long encoding times and 2D acceleration with a large array coil is expected to provide high acceleration capability. In this work a very high-speed method for 3D-MRSI based on the combination of proton echo planar spectroscopic imaging (PEPSI) with regularized 2D-SENSE reconstruction is developed. Regularization was performed by constraining the singular value decomposition of the encoding matrix to reduce the effect of low-value and overlapped coil sensitivities. The effects of spectral heterogeneity and discontinuities in coil sensitivity across the spectroscopic voxels were minimized by unaliasing the point spread function. As a result the contamination from extracranial lipids was reduced 1.6-fold on average compared to standard SENSE. We show that the acquisition of short-TE (15 ms) 3D-PEPSI at 3 T with a 32 × 32 × 8 spatial matrix using a 32-channel array coil can be accelerated 8-fold (R = 4 × 2) along y-z to achieve a minimum acquisition time of 1 min. Maps of the concentrations of N-acetyl-aspartate, creatine, choline, and glutamate were obtained with moderate reduction in spatial-spectral quality. The short acquisition time makes the method suitable for volumetric metabolite mapping in clinical studies. Magn Reson Med, 2007. © 2007 Wiley-Liss, Inc.
關聯 Magnetic Resonance in Medicine,58(6), 1107-1116
資料類型 article
DOI http://dx.doi.org/10.1002/mrm.21426
dc.contributor 應物所en_US
dc.creator (作者) Otazo, Ricardo ; Tsai, Shang-Yueh ; Lin, Fa-Hsuan ; Posse, Stefanen_US
dc.creator (作者) 蔡尚岳zh_TW
dc.date (日期) 2007.12en_US
dc.date.accessioned 10-Apr-2014 11:16:56 (UTC+8)-
dc.date.available 10-Apr-2014 11:16:56 (UTC+8)-
dc.date.issued (上傳時間) 10-Apr-2014 11:16:56 (UTC+8)-
dc.identifier.uri (URI) http://nccur.lib.nccu.edu.tw/handle/140.119/65243-
dc.description.abstract (摘要) MR spectroscopic imaging (MRSI) with whole brain coverage in clinically feasible acquisition times still remains a major challenge. A combination of MRSI with parallel imaging has shown promise to reduce the long encoding times and 2D acceleration with a large array coil is expected to provide high acceleration capability. In this work a very high-speed method for 3D-MRSI based on the combination of proton echo planar spectroscopic imaging (PEPSI) with regularized 2D-SENSE reconstruction is developed. Regularization was performed by constraining the singular value decomposition of the encoding matrix to reduce the effect of low-value and overlapped coil sensitivities. The effects of spectral heterogeneity and discontinuities in coil sensitivity across the spectroscopic voxels were minimized by unaliasing the point spread function. As a result the contamination from extracranial lipids was reduced 1.6-fold on average compared to standard SENSE. We show that the acquisition of short-TE (15 ms) 3D-PEPSI at 3 T with a 32 × 32 × 8 spatial matrix using a 32-channel array coil can be accelerated 8-fold (R = 4 × 2) along y-z to achieve a minimum acquisition time of 1 min. Maps of the concentrations of N-acetyl-aspartate, creatine, choline, and glutamate were obtained with moderate reduction in spatial-spectral quality. The short acquisition time makes the method suitable for volumetric metabolite mapping in clinical studies. Magn Reson Med, 2007. © 2007 Wiley-Liss, Inc.en_US
dc.format.extent 814881 bytes-
dc.format.mimetype application/pdf-
dc.language.iso en_US-
dc.relation (關聯) Magnetic Resonance in Medicine,58(6), 1107-1116en_US
dc.subject (關鍵詞) echo-planar spectroscopic imaging;parallel imaging;SENSE;regularization;large array coilen_US
dc.title (題名) Accelerated Short-TE 3D Proton Echo-Planar Spectroscopic Imaging using 2D-SENSE with a 32-Channel Array Coilen_US
dc.type (資料類型) articleen
dc.identifier.doi (DOI) 10.1002/mrm.21426en_US
dc.doi.uri (DOI) http://dx.doi.org/10.1002/mrm.21426 en_US